Radiographic Inspection

Radiographic Inspection

Talon radiographers have extensive experience in the casting and airframe inspection fields. The highly qualified staff, four X-ray vaults, large dark rooms and multi-station viewing areas result in exceptional throughput and lower cost. The four vaults are equipped with 320 KV for heavy alloys as well as a 150 KV and a 140 KV for lighter metallic radiographic requirements and composites. Components inspected include castings, EB welds, brazes and composite aircraft structures.


Radiographic Inspection Methods
  • Conventional Film X-Ray
  • Digital Radiography
Advantages of Radiographic Inspection
  • Can be used to inspect virtually all materials
  • Detects surface and subsurface defects
  • Ability to inspect complex shapes and multi-layered structures without disassembly
  • Minimum part preparation is required

Industrial radiography involves exposing a test object to penetrating radiation so that the radiation passes through the object being inspected and a recording medium placed against the opposite side of that object. For thinner or less dense materials such as aluminum, electrically generated x-radiation (X-rays) is used.

The recording media can be industrial x-ray film or one of several types of digital radiation detectors. With both, the radiation passing through the test object exposes the media, causing an end effect of having darker areas where more radiation has passed through the part and lighter areas where less radiation has penetrated.

If there is a void or defect in the part, more radiation passes through, causing a darker image on the film or detector.

Film radiography uses a film made up of a thin transparent plastic coated with a fine layer of silver bromide on one or both sides of the plastic. When exposed to radiation these crystals undergo a reaction that allows them, when developed, to convert to black metallic silver.

That silver is then "fixed" to the plastic during the developing process, and when dried, becomes a finished radiographic film.

To be a usable film, the area of interest (weld area, etc.) on the film must be within a certain density (darkness) range and must show enough contrast and sensitivity so that discontinuities of interest can be seen.

Radiographic Inspection

These items are a function of the strength of the radiation, the distance of the source from the film and the thickness of the part being inspected. If any of these parameters are not met, another exposure ("shot") must be made for that area of the part.

Digital radiography (DR) digitizes the radiation that passes through an object directly into an image that can be displayed on a computer monitor. The three principle technologies used in direct digital imaging are amorphous silicon, charge coupled devices (CCDs), and complementary metal oxide semiconductors (CMOSs). These images are available for viewing and analysis in seconds compared to the time needed to scan in computed radiography images.

The increased processing speed is a result of the unique construction of the pixels; an arrangement that also allows a superior resolution than is found in computed radiography and most film applications.

Real-time radiography (RTR), or real-time radioscopy, is a nondestructive test (NDT) method whereby an image is produced electronically, rather than on film, so that very little lag time occurs between the item being exposed to radiation and the resulting image.

In most instances, the electronic image that is viewed results from the radiation passing through the object being inspected and interacting with a screen of material that fluoresces or gives off light when the interaction occurs.

The fluorescent elements of the screen form the image much as the grains of silver form the image in film radiography. The image formed is a "positive image" since brighter areas on the image indicates where higher levels of transmitted radiation reached the screen. This image is the opposite of the negative image produced in film radiography. In other words, with RTR, the lighter, brighter areas represent thinner sections or less dense sections of the test object.


Have A Project For Us? Get in Touch


Camarillo, CA
  • Address: 650 Via Alondra,
    Camarillo, CA 93012
  • Phone: (805) 987-7755
  • Fax: (805) 987-6010

Chandler, AZ
  • Address: 6145 W. Detroit Street,
    Chandler, AZ 85226
  • Phone: (602) 454-2500
  • Fax: (602) 454-2515

Indianapolis, IN
  • Address: 915 Western Drive,
    Indianapolis, IN 46241
  • Phone: (317) 273-0633
  • Fax: (317) 672-3781
© 2015. « Talon Test Laboratories ». All right reserved.